Posts

200W DATV power amplifier- 50V 20A power supply

Image
200W DATV power amplifier- 50V 20A power supply Introduction I am builder a DATV power amplifier, about 200W maximum. The power supply is unusually powerful as the amplifiers are only bout 25 per cent efficient. Commissioning such a power supply is not simple. DATV power amplifier I discovered through one of the Yahoo groups that it was possible to buy UHF DVB-T pallet amplifiers, broad band from 470 MHz to 900 MHz. I bought one through the Italian eBay for 400 Euro. It has a pair of BLF888A  LDMOS transistors. The pallet is a pair of amplifiers with a splitter and combiner to allow single in and out. The BLF888A are each a match pair of transistors in push-pull. Power supply The power requirements are about 48V at 20A as the amplifiers are only about 25 percent with the ultra linear DVB-T. I remembered that a lot of telecommunications equipment use 48V, so had a look on eBay. I managed to buy a new  ELTEK Flatpack2 2000W 48V HE Power Supply...

Three cavity notch RX filter for 2 m with 1.6 MHz RX/TX spacing

Image
Three cavity notch RX filter for 2 m repeater with 1.6 MHz RX/TX spacing Introduction A three cavity notch filter was constructed and tested. The RX filter has over 80 dB of TX rejection. Construction The club has a 2 m repeater that is to operate on the new 1.6 MHz RX/TX spacing, as opposed to the usual 600 kHz spacing. The existing high/low pass reject cavities could not accommodate the wider spacing, limited to about a 1.1 MHz spacing. The club has five 1968 band pass filters, old but well made. A pair of them had been used with a phasing harness to act as notch filters, but the rejection was not high enough for TX reject on RX. Two are probably adequate for the TX filter to reject spurious noise at the RX frequency. I decided to try and make a three cavity notch RX filter, necessitating a new phasing harness. Each of the cables are a quarter wavelength, with those going to the cavities a little shorter to allow for the probe inside the cavity. I used LMR-400 ultraflex fo...

Duplexer isolation: limits of instrumentation

Image
Duplexer isolation: limits of instrumentation Introduction With high isolation duplexers, about 100 dB, conventional spectrum analysers and tracking generators are beyond their capability of about 80 dB. The rejection of a high isolation duplexer can be checked using a RF signal generator and spectrum analyser. High isolation duplexers. I have a couple of sets of four cavity 70 cm pass reject duplexers. The two cavities give about 70 dB rejection, which is ok but more would be better for RX. A third cavity can be added for greater isolation. Each cavity is individually tuned with a spectrum analyser and tracking generator. The two cavity duplexer can then be assembled and tested. A nice plot with about 70 dB rejection at 438.1 MHz and a pass of 433.1 MHz. Adding the third cavity results in noise at the rejection notch. The spectrum analyser cannot show the full depth of the notch; it does not have enough dynamic range. RF generator and spectrum analyser A RF...

Tuning the receiver front-end of a Kenwood TKR-750 repeater

Image
Tuning the receiver front-end of a Kenwood TKR-750 repeater Introduction I bought a second-hand Kenwood TKR-750-1 VHF repeater. However it was not clear what band the receiver was tuned to. The actual receiver and transmit frequencies can be programmed with a computer. However the the receiver band width is tuned with a spectrum analyser and tracking generator. This post describes how to re-tune the receiver front end. The band pass filters for a 2m repeater RX are quite critical as they are the only selectivity. With a 600 kHz spacing, the cavity filters are usually just isolating the TX and RX when sharing the same antenna, but providing no bandpass to strong nearby signals. Starting point and instrumentation I have an old HP8591A spectrum analyser and tracking generator, circa the 1990s, but still a capable instrument. The basic procedure is to connect the tracking generator output to the RX antenna input and the spectrum analyser input to a test point after the RX bandp...

Cavity resonators; size does matter and preview of my HP 8591A spectrum analyzer

Image
Cavity resonators; size does matter and preview of my HP 8591A spectrum analyzer The Q or quality of a cavity resonator or filter is critical. The simplest way of increasing Q is to increase the diameter. The club has been lent what seemed a pretty ordinary 2 m cavity resonator; even has UHF rather than N connectors and is light. I wasn't expecting too much. But it is 150 mm diameter compared to the 100 mm ex-government cavity filters the club has. The two cavity filters. Note that the filters are not tuned to the same frequency; but they are not too far apart to make a difference to Q. However, what a difference size makes! The Q is visibly much better. Note, none of the instruments were calibrated for this exercise, it is just to show the qualitative difference. First, the quick and dirty antenna analyzer and a 50 Ohm terminator. Then with the club's Rigol spectrum analyzer. Then with my recently acquired HP 8591A spectrum analyzer; 1990s...

HP 437B power meter: new toy; traps for beginners

Image
HP 437B power meter: new toy; traps for beginners Introduction and traps for beginners I have recently turned 60 and decided to get some new toys, in the form of stand-alone test equipment. For some odd reason, mainly curiosity, I decided a power meter would be useful, so I bought a 20 year old HP 437B power meter, with sensor and attenuators. Modern power meters of similar capability are about $10K or more! As well as being expensive, the meters are not particularly intuitive to use, primarily because they use a range of power sensors that have very different features, discussed in this post, as it is a trap for beginners. In my case, the sensor was too sensitive for the unit's calibration signal; requiring attenuators just to get the device working. Power measurement is not a simple task, other than for a unmodulated carrier; much less, a 7 MHz wide digital TV signal, especially DVB-T with 8000 carriers across its bandwidth.  Power measurement is not covered well in the l...

Problems of different metals in a cavity resonator: Galvanic series

Image
Problems of different metals in a cavity resonator: Galvanic series A problem building a cavity resonator is the potential of electrolytic corrosion between different metals, such as copper and aluminium. This can be overcome by keeping the cavities dry and using a sacrificial anode, such as zinc, already part of the design. The Galvanic series for metals in sea water is shown below. From the table mixing copper and aluminium, is potentially not a good idea. However...   A cavity usually resides in the same room as the repeaters that is usually dry, hence no electrolyte to enable galvanic corrosion. Putting the cavity outside is a different story.   Another sneaky trick is to use a sacrificial anode to protect the other metals. Zinc, in the form of galvanised steel can do this. An integral part of my cavity design is the use of galvanised threaded rod to hold everything in place. A secondary function is the galvanic protection of the device with the sacri...